Change Notice
Doc-To-Help Standard Manual
by Robelle Solutions Technology Inc.
Program
and manual copyright © 1981-2015 Robelle Solutions Technology Inc.
Permission is granted to reprint this document (but not for profit), provided that copyright notice is given.
Qedit and Suprtool are trademarks of Robelle Solutions Technology Inc. Oracle is a trademark of Oracle Corporation, Redwood City, California, USA. Other product and company names mentioned herein may be the trademarks of their respective owners.
Robelle Solutions Technology Inc.
Suite
372, 7360 137 Street
Surrey, BC Canada V3W 1A3
Phone: 604.501.2001
Fax: 604.501.2003
Support: 289.480.1060
E-mail: sales@robelle.com
E-mail: support@robelle.com
Web: www.robelle.com
Contents
Introducing
Suprtool Version 5.7 4
Overview............................................................................................................... 4
Highlights in Suprtool 5.7....................................................................................... 4
Highlights in
Suprtool 5.6....................................................................................... 5
Highlights in
Suprtool 5.5....................................................................................... 6
Known Problems.................................................................................................... 6
Itanium vs PA_RISC.............................................................................................. 6
Compatibility........................................................................................................ 8
Itanium
Compatibility............................................................................................. 9
CPU Serial Number (uname)................................................................................... 10
Documentation..................................................................................................... 10
Installation 11
Overview............................................................................................................. 11
Installation Instructions.......................................................................................... 11
Installation Assistance............................................................................................ 11
Introduction......................................................................................................... 12
stexpmgr............................................................................................................. 12
linkmgr............................................................................................................... 12
$Proper............................................................................................................... 12
$Translate............................................................................................................ 13
Enhancements in
Version 5.6 17
Introduction......................................................................................................... 17
Extract Command................................................................................................. 17
Data Items Support................................................................................................ 18
$SubCount.......................................................................................................... 18
CCTL on Output.................................................................................................. 19
Defined Items
Support............................................................................................ 19
Bugs Fixed 20
Bugs Fixed In
Suprtool 5.6.10................................................................................ 20
Bugs Fixed In
Suprtool 5.5.11................................................................................ 20
Bugs Fixed In
Suprtool 5.5.04................................................................................ 20
Bugs Fixed In
Suprtool 5.5.03................................................................................ 20
Bugs Fixed In
Suprtool 5.5.02................................................................................ 20
Bugs Fixed In
Suprtool 5.5.01................................................................................ 21
Bugs Fixed In
Suprtool 5.5.................................................................................... 21
Bugs Fixed In
Suprtool 5.4.................................................................................... 21
Use Suprtool/AMXW to read, select, and sort data from Oracle, Allbase and Eloquence databases and data files with fixed-length records. Suprtool/AMXW is designed to be similar to Suprtool for MPE while providing necessary HP-UX features. It is designed to work with AMXW an MPE environment from Speedware that runs on other platforms.
Suprlink/AMXW provides high-speed data-file linking based on a sort key. Use STExport for AMXW to convert fields in a self-describing input file into an output file that can be imported into different applications.
· Suprlink now has it’s own “Suprmgr” file. Suprlink
will process all the commands in /opt/robelle/linkmgr on startup.
· STExport now has it’s own “Suprmgr” file. STExport
will process all the commands in /opt/robelle/stexpmgr on startup.
· Suprtool for AMXW would not stop / abort Suprtool
when using the list command and the target file filled up.
· Suprtool now has the $proper function which will
shift the first character in a string and any first character after a space or
ampersand.
· Suprtool now has the Translate command and a
$translate function to obfuscate test data or any byte field from being
readable.
· Suprtool output,else with extract commands and sort in play would write
bogus data to the Else file. (non-MPE platforms)
· Suprtool for AMXW did not create a self-describing
file when output,link was specified and the input source was a non-self
describing flat file equated to a dataset. (Fixed in Build 2)
· Suprtool for Itanium and Suprtool/Open incorrectly reallocated if/extract code space on subsequent tasks, which would eventually cause Suprtool to fail with the error, “Unable to allocate heap space.”. This issue could also contribute to a Sort failure errors, in Suprtool for AMXW.
· Suprtool for AMXW had a conflict with the AMXW copy command when copying a C/ISAM or emulated KSAM file.
· Suprtool for AMXW could not append to an empty KSAM file.
· Suprtool, Suprlink and STExport now handle 512 fields on HP-UX and Open platforms.
· Suprtools' extract command now has three special keywords to help with extract using a range, which is designed to make your Suprtool scripts more easily maintained. Suprtool now has $all, $first and $last which respectively means all fields, the first field or the last field. Note that $first and $last may only be used in a range extract.
· $subcount has been added to keep a running count for a given sort break.
· Suprtool for HP-UX and AMXW would potentially incorrectly set the decimal or date attribute on a straight copy of an SD file. This was introduced by the fix to copying SD files with duplicate fieldnames and was in 5.5.04 pre-release and 5.5.11 and 5.6 Build 1. This is fixed in Suprtool 5.6 Build 2 and Suprtool/Open Build 3.
· Suprtool for AMXW would print an error message when doing a straight get of a dataset to a flat file with no extract command. (Fixed in Suprtool 5.6 Build 2)
· Suprtool for AMXW would not show fieldnames on a list of an SD file with no extract command. (Fixed in Suprtool 5.6 Build 2)
· Suprtool for AMXW will now detect if the output file has CCTL and will use the correct controlcode on the FWRITE to the Output file.
· Suprtool for AMXW Itanium version now supports more defined fields.
· Suprtool would use an incorrect field definition when copying a file where the input file had a duplicate field name with different field definition, the second field would utilize the first definition.
· Suprtool would give an incorrect result when doing an arithmetic expression with more than one set of brackets and the data involved is Packed-Decimal. (Itanium only)
· Suprtool and STExport would incorrectly assume a positive sign for a packed-decimal field that had an invalid sign value, when converting from Decimal to Ascii. (Itanium only)
· Suprtool for AMXW did not allocate enough space to support the same number of defined fields and items as previous versions.
· Set Ifouroutput on
extracts would fail at xeq time with an "Unknown if execute phase" error in the PA_RISC version,
when an alignment
issue would occur in some
circumstances.
· Suprtool for AMXW would fail to open a "KSAM" file in AMXW when the implementation was done via CISAM.
· Set Fastread Off is now the default for Suprtool for AMXW when accessing Eloquence databases.
· Suprlink for AMXW would fail on a Join command after a patch to libc was applied.
·
Set Oracle DataBug On | Off has been added to mimic the incorrect
behaviour of writing double the number of bytes in versions 5.1 thru 5.4 and if
no extract commands were in place and either set ifouroutput or set oracle
integer were on and the input source was an Oracle table.
· The $edit function did not work properly with alpha based edit masks and if the target was greater than 32 characters.
· Suprtool2 for AMXW did not initialize jcw to zero. (Build 6)
· Suprtool for AMXW with varsub on would fail with an if $read expression. (Build 6)
There are no known problems at this time. If you have any questions or concerns or feedback, please feel free to e-mail me at: neil@robelle.com
There are two types of machines that HP has that run HP-UX, the older machines are based on the PA_RISC chip and the new machines that use the Itanium (and Itanium 2 chips). There are also program files that are specific to each chip. PA_RISC programs can run on both PA_RISC and Itanium machines, however, Itanium programs can only run on Itanium machines.
Any program that runs on Itanium must utilize libraries that match its own program type. Therefore if a PA_RISC program runs on Itanium and looks for a library, it must find/load the PA_RISC version of the libraries that it needs and conversely an Itanium program must load the libraries specific to its type.
How
to Tell what Machine I am on?
There are many ways to tell what kind of machine you are on, here are a couple:
uname -m
getconf MACHINE_MODEL
In each case the Itanium machine will typically say ia64 somewhere in the result of the above two commands. PA_RISC machines typically say "9000" somewhere in the string.
What
is the Program File Type?
Since there are two types of machines there are also at least two types of program files. Suprtool is primarily either PA_RISC 1.1 or ELF-32 / IA64 which is also known as Itanium. To determine the type of program file you can use the file command:
Itanium
file suprtool
suprtool: ELF-32 executable object file - IA64
PA_RISC
file suprtool
suprtool: PA-RISC1.1 executable dynamically linked -not stripped
The PA_RISC binary can run on both platforms but you need to have PA_RISC libraries for Eloquence or Oracle if you are using the Oracle module. An Itanium binary will not run on a PA_RISC machine and will fail with "cannot execute".
Of course we've made a provision to identify if you are running the ia version of Suprtool in the banner and verify command with the ia after the UX :
SUPRTOOL/UXia/Copyright Robelle Solutions Technology Inc. 1981-2009.
(Version 5.2 Internal) MON, JUN 8, 2009, 11:26 AM Type H for help.
PA_RISC
Loading
Suprtool by default looks in the libraries in any of the directories named in SHLIB_PATH. For example to insure that Suprtool resolves the library loads you can set the SHLIB_PATH system wide in your /etc/profile file in the following manner:
export SHLIB_PATH=/opt/eloquence6/lib/pa11_32:/opt/oracle/lib
If you do not have the SHLIB_PATH variable set to a value where the libraries can be found, Suprtool will then try to load from their default names locations. For Eloquence the default location is :/opt/eloquence6/lib/pa11_32.
The Oracle interface will first try to load libclntsh.so and then attempt to load libclntsh.sl from $ORACLE_HOME/lib32/libclntsh.sl.
Itanium
Loading
You can change Suprtool to pay attention to LD_LIBRARY_PATH and use dlopen to load libraries, you can set the environment variable:
export ROBELLE_DYN_LOAD =Y.
It is generally advisable to use DLOPEN or the ROBELLE_DYN_LOAD option when using the Itanium version. The PA_RISC version of Suprtool can use either type of loading, the default or the dlopen method invoked with ROBELLE_DYN_LOAD.
Running
the PA_RISC version on Itanium:
You can of course run the PA_RISC version of Suprtool, however, given that the PA_RISC version requires SHLIB_PATH to point to PA_RISC libraries may go against the configuration necessary for other programs that may need SHLIB_PATH to point to Native Itanium libraries.
The solution to this is fairly simple, you can create a command file (let's say /opt/robelle/cmd/suprtool) that runs suprtool for you, of course you need to insure your path variable has /opt/robelle/cmd before /opt/robelle/bin.
You can then have the following commands in the /opt/robelle/cmd/suprtool command file:
export SAVED_SHLIB_PATH=$SHLIB_PATH
export SHLIB_PATH=/opt/oracle/pa_risc/lib:/opt/eloquence/lib/pa11_32
/opt/robelle/bin/suprtool $@
export SHLIB_PATH=$SAVED_SHLIB
Essentially all it does save the current SHLIB_PATH setting, sets it to point to PA_RISC libraries, runs suprtool and then resets the library back.
Suprtool
for Itanium
Now that you know all about PA_RISC and Itanium you do need to be aware of what Suprtool for Itanium is in terms of new code and risk for potential issues. Suprtool for Itanium is completely in C code. This does not mean that it is all new C code however, the majority of the Suprtool code is still based on SPL, but is converted to C, using Allegro's SPLASH compiler.
So while the C code is new it is based on the original SPLash code, however, given differences between C and SPLash not all code can be automatically converted in some cases. We worked closely with Allegro to find ways to have the source code work and address the various issues that came up. The entire time Allegro improved the SPLash to C converter.
So while we are based on the original Suprtool we do have new code paths in the Native Itanium version and other potential issues where the C code might not work in exactly the same manner as the SPLash code.
Having said that we have tested this against our test suites, and improved and added a large number of tests to our HP-UX test suites. We also began Alpha testing 24 months ago and have been beta testing for the last year with our two best VAR customers.
Suprtool for AMXW would use the file
size stored in the SD label as opposed to the actual physical file size that
AMXW uses.
::FILE
FILE80;REC=-80,,F,ASCII
::supramxw
SUPRTOOL/AMXW/Copyright Robelle Solutions Technology Inc.1981-2007.
(Version 5.0) TUE, JAN 08, 2008, 2:42 PM Type H for help.
>I STFILE
>DEF ABCXYZ,1,11
>EXT ABCXYZ
>O FILE80,LINK
>X
IN=26, OUT=26. CPU-Sec=1. Wall-Sec=1.
>FO FILE80
File: FILE80 (SD Version B.00.00) No linefeeds
Entry:
Offset
ABCXYZ
X11 1
Limit: 1023 EOF: 26 Entry Length: 11 Blocking: 1
>E
::LISTF FILE80,2
ACCOUNT= AMXWQA GROUP= FDE
FILENAME
CODE ------------LOGICAL RECORD----------- ----SPACE----
SIZE TYP
EOF LIMIT R/B SECTORS #X MX
FILE80 1084 82B FA 26 1023 1 9 1 *
So what happens is if an output link
file is created with a file equation making the file bigger, any subsequent
files that are created from the resulting output file are actually made smaller
as you can see below.
::supramxw
SUPRTOOL/AMXW/Copyright Robelle Solutions Technology Inc.1981-2007.
(Version 5.0) TUE, JAN 08, 2008, 2:42 PM Type H for help.
>i FILE80
>O FILE80A
>X
Warning: Using Output FILE80A,Link
IN=26, OUT=26. CPU-Sec=1. Wall-Sec=1.
>E
::LISTF FILE80A,2
ACCOUNT=
AMXWQA GROUP= FDE
FILENAME
CODE ------------LOGICAL RECORD----------- ----SPACE----
SIZE TYP
EOF LIMIT R/B SECTORS #X MX
FILE80A
1084 11B
FA
26 1023
1 2 1 *
Suprtool for AMXW now honours
the physical record size and the FILE80A file will now have a record size of
80.
The HP-UX and AMXW versions of AMXW no
longer have Set varsubcompat on as the default.
The default is now off and can be turned on with the set command or the
–cv option.
Previously, Suprtool would treat an “R” type field in an Eloquence database as an R type while the data inside Eloquence is stored and treated as IEEE therefore incorrect results would occur with coercions and arithmetic operations. Suprtool now by default maps all Real and Long fields to their respective IEEE fields. You can change Suprtool back to the previous behaviour with Set RealMap Off.
A form command will still show the fields as being “R2” or “R4”, but internally Suprtool will treat as IEEE, which is how Eloquence stores and treats the numbers.
Consequently STExport will now support items in SD files that are condidered R type, however it correctly will map them to IEEE.
Suprtool/UX 5.0 is now compatible with all versions of HP-UX 11.2x, as well as Oracle version 8 and higher.
Suprtool/UX version 4.8.02 and lower is compatible with HP-UX 9.0 and higher and Oracle 7.
Fastread option is now set to On for Suprtool for HP-UX the regular version. The Dynamic loading version of Suprtool has a default value of off to start.
Suprtool 5.2 is necessary for use with Oracle 11 and case sensitive passwords.
There are a couple of differences in the Itanium version of Suprtool, which you need to be aware of.
The
DBEdit module is not available in the Itanium versions of Suprtool. This module
is invoked by the EDIT command.
The
layout for the Verify command is slightly different then the PA-RISC versions
of Suprtool.
This program runs only on CPUs whose serial numbers have been encoded (the "uname" on HP-UX). If it fails to run and you get an "invalid HPSUSAN" error message, contact Robelle for assistance, via support@robelle.com or the support number at 1-800-453-8970.
The
user manual contains the full description of all the Suprtool suite of products
including Dbedit, Suprlink, STExport, and Suprtool2, as well as usage tips and
commands for each. The manuals are up-to-date with all the latest changes. To
see only the changes in the latest version, see the "What's New"
section of the manual.
You
can download our manuals and Change Notices in various formats and order
printed (hardcopy) manuals from our web site at:
http://www.robelle.com/library/manuals/.
The following instructions describe the installation process of a new Suprtool release. The new version overwrites an existing version of Suprtool on your HP-UX system.
There are typically two main types of installations. You can find the Suprtool for AMXW regular install instructions here:
http://www.robelle.com/downloads/install-amxwprod.html
You can find the Suprtool for AMXW build on your system instructions on the link below. You will need this install if you are going to require the KSAM option, Dynamic Image loading or Omnidex support, or intend to run on Itanium:
http://www.robelle.com/downloads/install-amxwbuildprod.html
If you have any questions or run into any problems, please call us. Technical support is available on weekdays from 8 a.m. to 4 p.m. Pacific time at 1.289.480.1060. Technical support can also be obtained via e-mail at: support@robelle.com If your new version of software will not run, you can page someone from technical support by calling the support number, or you can typically easily run extend with the disaster option to tide you over until business hours. Instructions for this are available at:
http://www.robelle.com/disaster/
Enhancements in
Version 5.7
Suprtool
is constantly being updated with new features. The following section describes
the new enhancements to Suprtool since Suprtool 5.6.
STExport now has it’s own “suprmgr” file
now, which will be executed on startup of STExport. STExport will by default
look for /opt/robelle/stexpmgr, or if $ROBELLE variable is set it will execute
$ROBELLE/stexpmgr.
Suprlink now has it’s own “suprmgr” file
now, which will be executed on startup of Suprlink. Suprlink will by default
look for /opt/robelle/linkmgr, or if $ROBELLE variable is set it will execute
$ROBELLE/linkmgr.
Suprtool now has the $proper function which will shift to upper case the first character of a byte type field and after any space or ampersand. It will also shift to lower case any other characters in the byte-field.
>in mprod
>list stan
>xeq
Apr 29, 2014 13:00 File: mprod Page 1
PRODUCT-DESC
skil 3/8" variable speed drill
b&d router
skil var. sp. auto-scroll saw
skil 8 1/2" circular saw
b&d cordless screwdriver
makita 8 1/4" circular saw
b&d variable speed jigsaw
makita 1/2" router
makita 3/8" var. speed drill
skil router
b&d 7 1/4" circular saw
b&d 3/8" variable speed drill
makita 1" jigsaw
Considering the following data, you can fix all of the product names with one simple task:
>in mprod
>ext product-desc=$proper(product-desc)
>list stan
>xeq
May 01, 2014 11:40 File: MPROD Page 1
PRODUCT-DESC
Skil 3/8" Variable Speed Drill
B&D Router
Skil Var. Sp. Auto-Scroll Saw
Skil 8 1/2" Circular Saw
B&D Cordless Screwdriver
Makita 8 1/4" Circular Saw
B&D Variable Speed Jig Saw
Makita 1/2" Router
Makita 3/8" Var. Speed Drill
Skil Router
B&D 7 1/4" Circular Saw
B&D 3/8" Variable Speed Drill
Makita 1" Jig Saw
Note that any character after a space, “&”, or “-“ is upshifted for a proper name. Suprtool will also downshift those characters that do not qualify as needing proper capitalization and it is a capital character, the proper function will downshift those characters. See an example below:
>IN NAME
>LIST
>XEQ
>IN NAME.NEIL.GREEN (0) >OUT $NULL (0)
NAME
= NEIL ARMSTRONG
>IN NAME
>EXT NAME=$PROPER(NAME)
>LIST
>XEQ
>IN NAME.NEIL.GREEN (0) >OUT $NULL (0)
NAME
= Neil Armstrong
The $proper function only works on byte type fields. (5.6.12)
Suprtool now has a $translate function which in conjunction with the translate command allows you to build a translation table, whereby you can translate from any byte character to any character. We have also added a method to a supplied translate table which will allow you to obscure the data such that it can’t be read.
>in
newprod
>list
>xeq
>IN
NEWPROD.NEIL.GREEN (0) >OUT $NULL (0)
PRODUCT-DESC = Skil 3/8" Variable Speed Drill
>IN
NEWPROD.NEIL.GREEN (1) >OUT $NULL (1)
PRODUCT-DESC = B&D Router
>in
newprod
>translate
tounread
>ext
product-desc=$translate(product-desc)
>out
unread,link
>xeq
IN=13,
OUT=13. CPU-Sec=1. Wall-Sec=1.
>in
unread
>num
1
>list
>xeq
>IN
UNREAD.NEIL.GREEN (0) >OUT $NULL (0)
PRODUCT-DESC =
Hzxo .2)? Epcxpqot Hatts Rcxoo
Warning: NUMRECS exceeded; some records not processed.
IN=2,
OUT=1. CPU-Sec=1. Wall-Sec=1.
>in
unread
>translate
toread
>ext
product-desc=$translate(product-desc)
>list
>xeq
>IN
UNREAD.NEIL.GREEN (0) >OUT $NULL (0)
PRODUCT-DESC = Skil 3/8" Variable Speed Drill
>IN
UNREAD.NEIL.GREEN (1) >OUT $NULL (1)
PRODUCT-DESC = B&D Router
You
can make your own Translate table using the Translate command, where you can
specify the character you want to translate and what you want to translate to,
using Decimal Notation. So if you want to translate “A” to “Z”, you would type
the command:
Translate “^65:^90”
So you
specify the from character on the left in decimal which is the capital-A and
the to-character is also in decimal format which is capital-Z, which is decimal
90. If you want to reverse the translation you can simply do the following
command and translate the field back with:
Translate “^90:^65”
This is not meant to be an encryption
solution, but it will help obfuscate test date really quickly. (5.6.12)
Suprtool
is constantly being updated with new features. The following section describes
the new enhancements to Suprtool since Suprtool 5.5
Suprtool's extract command now has three new keywords, which can be used for extract range feature. You can now say extract $all, extract $first / $last on an SD file or Image/Eloquence dataset. The intention is to make your scripts more easily maintained. If you had a script that you wanted to put a sequence number at the beginning and then extract the rest of the dataset you previously had to specify the starting field and the ending field. For example if the first field in a dataset was order-no and the last field was pst-code you may have a script that looked like this.
base orddb
get customers
def seq-no,1,4,double
ext seq-no=$counter
ext order-no / pst-code
out newfile,link
xeq
If you added any fields to the beginning or end of the dataset you would have to re-write the script. Now you can write the script as being:
base orddb
get customers
def seq-no,1,4,double
ext seq-no=$counter
ext $all
out newfile,link
xeq
You can also write the script using $first / $last as your preference, but $first and $last are also useful if you need to add data into the middle of the fields you extract:
base orddb
get customers
def seq-no,1,4,double
ext $first / zip
ext seq-no=$counter
ext tax-code / $last
out newfile,link
xeq
Please note that if a self-describing file has a fieldname that is a duplicate field and one of the duplicate fields is the last field in the file, then $first / $last and $all, will only extract up to the first occurrence of the duplicate fieldname. This may seem as an issue but it is consistent with what Suprtool does currently with extract from a range. Currently and prior to the $first / $last enhancement Suprtool would have extracted only up to the first occurrence of the field if you had a file such as this:
>form
File: newfile (SD Version
B.00.00) Has linefeeds
Entry: Offset
CHAR-FIELD X5 1
INT-FIELD I1 6
DBL-FIELD I2 8
PACKED-FIELD P12
12
PACKED*-FIELD P12
18
QUAD-FIELD I4 24
ID-FIELD I1 32
LOGICAL-FIELD K1
34
DBLLOG-FIELD K2
36
ZONED-FIELD Z5
40
FILLER X36 45
FILLER X36
81
Entry Length: 116 Blocking: 1
Notice that FILLER is a duplicate named field, so if you entered,
extract char-field / filler, Suprtool would only extract up to and including
the first FILLER field. For consistency, extract $first / $last behaves the
same way.
Suprtool now supports 512 data items in both Eloquence datasets and SD files and Oracle fields. STExport and Suprlink have also been updated to support the increased number of data items in the SD fields that they read, but please note that other limitations still exist. [5.5.10]
$SubCount has been added to provide a counter that only gets reset at a given sort break.
In file1sd
Sort char-field
Def control-count,1,4,double
Ext $first / $last
Ext control-count=$subcount(char-field)
Out newfile,link
xeq
What Suprtool will do in this case is start incrementing a number starting with 1, and increase by 1 for any given char-field value. This way you can add a counter based on a sort break for a given field.
Suprtool for AMXW now detects if the output file has cctl and if it does it will now use the correct controlcode on FWRITE.
Suprtool for AMXW now supports a greater number of defined items, equivalent to what Suprtool for MPE supports.
If Command. Suprtool for Itanium and
Suprtool/Open incorrectly reallocated if/extract code space on subsequent
tasks, which would eventually cause Suprtool to fail with the error, “Unable to
allocate heap space.”
COPY command. Suprtool for AMXW had a
conflict and would fail when copying a C/ISAM file from inside Suprtool.
SD File Copy. Suprtool would use an
incorrect field definition on a straight copy of an SD file if the input file
had a duplicate field name with different byte lengths. (HP-UX only)
Extract Command. Suprtool would give an
incorrect result when doing an Arithmetic Expression that has more than one set
of brackets as in: extract amt-p=(packed-field + packed-field) –
(packed-field *2) (Itanium only)
Decimal to Ascii. Suprtool and STExport would incorrectly assume a positive sign for a packed-decimal field that had an invalid sign value, when converting from Decimal to Ascii. (Itanium only)
Ifouroutput. Set Ifouroutput
on extracts would fail at xeq
time with an "Unknown if execute
phase" error in the PA_RISC
version, when an alignment issue
would occur in some circumstances.
KSAM files. Suprtool for AMXW would
fail to open a "KSAM" file in AMXW when the implementation was done
via CISAM.
Fields. Suprtool for AMXW did not allocate enough space to support the same
number of defined fields and items as previous versions.
$edit function. The $edit function did not work well with alpha based edit masks and if the target was greater than 32 characters.
Output,data. Suprtool would write out double the calculated record size when set oracle integer was on or set ifouroutput was on, and output,data option was used and no extract commands were specified.
Packed Data. Suprtool for HP-UX on Itanium would incorrectly coerce the number negative 65536 from Binary to Decimal and Decimal to Binary.
External Programs.. An external program would fail to be loaded to run when attempted to be run from inside Suprtool Itanium
Table Command. Suprtool did not properly clear the data field information from a table at the end of a task.
Extract from Table. Suprtool did not properly zero out a packed field target when an table entry was not found when extracting data from a table and the Packed field was P12 or higher.